Experience • Engineering

Cheyenne BOPU Southern Sewer Phase 1

  • Client Cheyenne Board of Public Utilities

  • Location Cheyenne, Wyoming

  • Services Design, Construction Oversight

Project Highlights

  • Designed and oversaw construction of 14,700 line-feet of gravity sanitary sewer pipe ranging in size from 27-inch to 36-inch, 2,950 line-feet of dual 18-inch sanitary force mains, 2,200 line-feet of 12-inch gravity sanitary sewer, 780 line-feet of 42-inch trenchless steel casing pipe, 57 manholes, a 4.0 MGD sewage lift station, and all other appurtenances.

  • Acted as local point of contact for the construction management, attended all weekly progress meetings, observed the construction daily, and worked with the Board of Public Utilities and the contractor to aid in the project progress.

  • Teamed with Burns & McDonnell.